AdapterId 0602Ah AdapterName "MetraByte uCCOM-422 RS-232/422 Communications Interface" NumBytes 3 NamedItem Prompt "Standard Communications Port Selection" choice "SERIAL_1" pos[2]=11111000b pos[1]=00000011b pos[0]=0100XXXXb io 03F8h-03FFh int 4 choice "SERIAL_2" pos[2]=11111000b pos[1]=00000010b pos[0]=0011XXXXb io 02F8h-02FFh int 3 choice "SERIAL_3" pos[2]=00100000b pos[1]=00110010b pos[0]=0011XXXXb io 3220h-3227h int 3 choice "SERIAL_4" pos[2]=00101000b pos[1]=00110010b pos[0]=0011XXXXb io 3228h-322Fh int 3 choice "SERIAL_5" pos[2]=00100000b pos[1]=01000010b pos[0]=0011XXXXb io 4220h-4227h int 3 choice "SERIAL_6" pos[2]=00101000b pos[1]=01000010b pos[0]=0011XXXXb io 4228h-422Fh int 3 choice "SERIAL_7" pos[2]=00100000b pos[1]=01010010b pos[0]=0011XXXXb io 5220h-5227h int 3 choice "SERIAL_8" pos[2]=00101000b pos[1]=01010010b pos[0]=0011XXXXb io 5228h-522Fh int 3 Help "Choose from standard COM1: - COM8: assignments. Note the PS/2 includes a standard COM1: port so this choice will normally be unavailable. The uCCOM-422 can also be set to any I/O address on an 8 bit boundary and any Micro Channel interrupt level. Use a word processor to change @602A.ADF for special selections." NamedItem Prompt "Protocol" choice "RS-232 with RTS/DTR/CTS" pos[0]=XXXX101Xb choice "RS-232 no control signals" pos[0]=XXXX001Xb choice "RS-422 with RTS/CTS" pos[0]=XXXX110Xb choice "RS-422 no control signals" pos[0]=XXXX010Xb Help "Choose RS-232 (lower connector) or RS-422 mode (upper connector). You cannot enable both RS-232 and RS-422 simultaneously. You can either enable or ignore standard control signals, CTS - Clear to Send, RTS - Request to send and for RS-232 only, DTR - Data Terminal Ready."