AdapterId 06EFFh AdapterName "CLEO MC/201/212AT Modem" NumBytes 1 NamedItem Prompt "I/O Address Range" choice "260h - 26Fh" pos[0]=00XXXXXXb io 0260h-026Fh choice "660h - 66Fh" pos[0]=10XXXXXXb io 0660h-066Fh choice "A60h - A6Fh" pos[0]=01XXXXXXb io 0A60h-0A6Fh choice "E60h - E6Fh" pos[0]=11XXXXXXb io 0E60h-0E6Fh Help "The CLEO MC/201/212AT Modem can be configured to operate at one of four Input/Output Address Ranges. This allows up to four modems to be installed in the system at the same time. The default address range is 260h-26Fh." NamedItem Prompt "Interrupt Request Level" choice "IRQ 3" pos[0]=XX0001XXb int 3 choice "IRQ 4" pos[0]=XX0011XXb int 4 choice "IRQ 5" pos[0]=XX0101XXb int 5 choice "IRQ 6" pos[0]=XX0111XXb int 6 choice "IRQ 7" pos[0]=XX1001XXb int 7 choice "IRQ 9/2" pos[0]=XX1011XXb int 9 choice "IRQ 10" pos[0]=XX1101XXb int 10 choice "IRQ 11" pos[0]=XX1111XXb int 11 choice "No IRQ" pos[0]=XX0000XXb Help "The CLEO MC/201/212AT Modem can be configured to operate on one of eight Interrupt ReQuest levels (IRQs). The default is IRQ 3. You may also choose to disable interrupts on any level." NamedItem Prompt "Phase Shift" choice "BELL 201 (United States)" pos[0]=XXXXXX1Xb choice "CCITT V.26A (Europe)" pos[0]=XXXXXX0Xb Help "The CLEO MC/201/212AT Modem can be configured to operate at one of two different phase shifts. Select BELL if the modem is to be used in the U.S. Select CCITT if the modem is to be used in Europe. The default phase shift select is BELL (United States)."