Introduction | Buses | Modules | Systems | Chips | Miscellany |
Configurations using a single module must locate that module in slot 0 (the lower one).
The last available BootPROM is version 2.25 from Sun, or 2.25R from Ross/Bridgepoint.
The Ross 2.25R PROM enables RT620D-based HyperSPARC modules. The Sun 2.25 PROM does not.
The Sun 2.25 PROM works with SM52, at least some SM52X, and (at least in part) with SM51-2, SM61-2, SM81-2 and pairs of some SM40 modules. The Ross 2.25R PROM might not.
There may be other differences.
The Ross 2.25R PROM can often be distinguished by the word "splug" on the label.
However, some configurations are still considered risky.
Configurations rated as deadly should not be used without additional cooling, ie: external fans to push more and cooler air into the PSU intake at the right-hand side of the chassis (when viewed from the front).
Configurations rated as very hot should not be used in fully-populated systems (ie: no free SBus slots, and more than four DSIMMs/VSIMMs) without great care, or at least some additional cooling.
Also, the ZX and TurboZX (Leo) SBus graphics cards generate a huge amount of heat; the TurboZX draws a mind-boggling amount of power from four (yes, power from all four) SBus slots. If you have a ZX or TurboZX card installed, you should avoid configurations rated very hot; in the case of TurboZX, you should also avoid configurations rated merely fairly hot.
Similar precautions might be prudent if you have a Fujitsu AG-10 graphics card installed.
Prolonged disregard for the above guidelines is likely to result in damage:
MBus Clock | Jumpers |
---|---|
Automatically selected 40MHz or 50MHz (factory setting) |
J1401: jumper on pins 2-3 |
Fixed at 40 MHz | J1401: jumper on pins 1-2 |
NOTE: the SS20 clock-speed jumper should be in the factory-preset (auto-select) position, except where noted in the module configuration table.
Inserting cards into (or extracting from) the top MBus slot requires temporary removal of any DSIMM or VSIMM in slot 4 for the duration of the insertion (or extraction) procedure.
See also: General Module Configuration Rules, which also covers mixed-module configurations.
Note: some configurations have particular caveats, such as failing to provide the level of performance that one might intuitively expect, or dangerous overheating, and so on. Such configurations are marked with a footnote-number in square brackets.
Module Type | No. of (identical) Modules |
Functional? | Min. PROM level | |||
---|---|---|---|---|---|---|
CYM6001K | 1 | yes [10] | 2.12 | |||
2 | no | n/a | ||||
SM100 | 1 | yes [11] | 2.12 | |||
2 | ||||||
SM20 SM21 SM30 |
1 | no | n/a | |||
2 | ||||||
|
1 | yes [1] | 2.12 | |||
2 | no | n/a | ||||
|
1 | yes [1] | 2.12 | |||
2 | 2.14 | |||||
|
1 | no | n/a | |||
2 | ||||||
|
1 | yes | 2.12 | |||
2 | ||||||
SM52 | 1 | yes [2] [8] | 2.12? | |||
2 | yes [2] [9] | |||||
|
1 | probably [2] | 2.12 | |||
2 | ||||||
|
1 | yes [3] | 2.12 | |||
2 | ||||||
|
1 | yes [1] | 2.12 | |||
2 | ||||||
SM520 | 1 | yes | 2.12 [6] or 2.25 | |||
2 | ||||||
SM521 | 1 | no | n/a | |||
2 | ||||||
SM50 | 1 | yes | 2.12 | |||
2 | ||||||
|
1 | probably [2] | 2.12 | |||
2 | ||||||
|
1 | yes [4] | 2.12 | |||
2 | ||||||
|
1 | yes [1] | 2.12 | |||
2 | ||||||
|
1 | yes [2] | 2.12 | |||
2 | ||||||
|
1 | yes | 2.12 | |||
2 | ||||||
SM51-2 | 1 | yes [1] [5] | 2.12 | |||
2 | ||||||
SM61-2 | 1 | yes [5] | 2.12 | |||
2 | ||||||
SM71 | 1 | yes | 2.22 | |||
2 | yes [7] | |||||
SM81 | 1 | yes | 2.22 | |||
2 | yes [8] | |||||
SM81-2 SM91-2 |
1 | yes [5] | 2.22 | |||
2 | yes [5] [8] | |||||
HMx1S-256 | 1 | no | n/a | |||
2 | ||||||
HM55any-256 HM66any-256 |
1 | yes [2] | 2.19 | |||
2 | ||||||
HM72any-256 HM80S-256 HM90any-256 HM100any-256 HM110D-256 HM125any-256 |
1 | yes | 2.19 | |||
2 | ||||||
HM110any-1024 HM125any-512 HM125any-1024 HM133any-512 HM142S-1024 |
1 | yes | 2.25 and 2.25R | |||
2 | ||||||
HM142W-1024 HM150S-512 HM166S-512 |
1 | yes | 2.25 and 2.25R | |||
2 | yes [7] | |||||
HM150D-512 | 1 | yes | 2.25 and 2.25R | |||
2 | yes [8] | |||||
HM150W-512 | 1 | yes | (2.25 and 2.25R) | |||
2 | yes [7] | |||||
HM180S-512 HM180D-512 |
1 | yes | 2.25R | |||
2 | ||||||
HMx4.5S-512 | 1 | yes [3] | 2.25R | |||
2 | ||||||
HMx4S-512 HMx4D-512 |
1 | yes | 2.25R | |||
2 |
Introduction | Buses | Modules | Systems | Chips | Miscellany |
Mike Spooner, revised 16th June 2004 |